Company News

Copper bar bending sampling test

Views : 712
Update time : 2022-05-26 14:24:23

Copper bars are widely used in electrical equipment, especially in complete power distribution units, because copper has better conductivity than aluminum. Generally, copper bars are used for phase A, B, C, and N bus bars and PE bus bars in A power distribution cabinet. Copper bar is generally marked with phase color letter logo or painted with phase color paint in use. A phase copper bar is marked with "yellow" color, B phase is "green" color, C phase is "red" color, N phase is "light blue" color, and PE bus bar is "yellow and green" double color.

copper platoon is mainly used on a line (high current phase line and zero line, the ground can use copper platoon), in a electric ark bigger current components connection is done with copper platoon, such as a line of electrical cabinets connection between tank and tank is the mistress, mistress row assigned to each electric switch of electric cabinet (isolating switch, breaker etc.) is a branch on the bus.

There are tinned copper bars and bare copper bars. Tin plating, embossing or conductive paste can be done at the connection of copper bars in the electric cabinet. Spare parts can be heated shrink casing protection, some are insulating paint. The main consideration with copper bar is the current, according to the size of the current to choose the suitable copper bar, the screw at the connection must be tightened, otherwise the current will be large when the possibility of burning copper bar.

Two straight samples were cut, the sample thickness should be the thickness of thin plate or thin strip products, and two original surfaces were retained; Machine added sample, its width should be 20-25mm, for width less than 20mm thin strip products, sample width should be the full width of the original product, sample length is 150mm. The cutting position and direction of the sample shall be in accordance with relevant product standards. Samples should be prepared so that the effects of heat and work hardening are minimized. Small, the sample surface should not crack and scar, edge should not burr. The relationship between the length of specimen L and the diameter of bent cylinder D and the thickness or diameter of specimen A is L=0.5π(D + A) +140 (mm).

The wide edge of the copper and copper alloy bus should be bent 90 degrees, and the surface should not crack. The diameter of the bent cylinder should be choosed according to the size of the thickness A in accordance with the national standard.

Related News
Read More >>
Cu-OF Copper Busbar: Oxygen-Free Conductivity for Power Distribution and Battery Systems Cu-OF Copper Busbar: Oxygen-Free Conductivity for Power Distribution and Battery Systems
Oct .24.2026
Cu-OF Copper Busbar delivers high electrical conductivity and reliable joints for switchgear, battery packs, inverters, and high-current power distribution.
Silicon Bronze Wire: Stable Conductivity for Welding, Fasteners, and Electrical Assemblies Silicon Bronze Wire: Stable Conductivity for Welding, Fasteners, and Electrical Assemblies
Oct .10.2026
Silicon bronze wire combines dependable conductivity with corrosion resistance and good formability for welding, fasteners, marine hardware, and electrical assemblies.
Aluminum Bronze Tube: Corrosion-Resistant Tubing for Pumps, Valves, and Marine Equipment Aluminum Bronze Tube: Corrosion-Resistant Tubing for Pumps, Valves, and Marine Equipment
Sep .26.2026
Aluminum bronze tube combines seawater corrosion resistance with dependable strength for pump bodies, valve components, heat exchangers, and marine fluid systems.
Phosphor Bronze Sheet: Spring Recovery and Conductivity for Connectors, Switches, and Precision Contacts Phosphor Bronze Sheet: Spring Recovery and Conductivity for Connectors, Switches, and Precision Contacts
Sep .12.2026
Phosphor bronze sheet combines dependable spring recovery with stable electrical conductivity, making it a practical material for connectors, switches, and precision contact parts.